Chemical Composition Of 16Mo3

Mar 25, 2024

  • Chemical composition (melt analysis)a, %

C: 0.12-0.20 b

Si: ≤0.35

Mn: 0.40-0.90

P max: 0.025

S max: 0.020

Cr:≤0.30

Mo: 0.25-0.35

Ni: ≤0.30

Al total: ≤0.040

Cu: ≤0.30 c

a Without the consent of the ordering party, elements other than those in this table shall not be intentionally added, except for those elements that must be added in the smelting process, and harmful elements brought into the steelmaking process shall be avoided as far as possible.
b Wall thickness ≥30mm carbon content can be increased by another 0.02%.
c (Optional): To facilitate the later molding process, a lower maximum copper content may be stipulated with the agreement of the buyer and seller, and the maximum tin content may be limited.

  • Heat Treatment:

Normalized or normalised rolled

Temperature: 890 - 950 °C

Cooling medium: Air

16Mo3 alloy boiler tube

  • Mechanical properties

Room temperature or low-temperature tensile properties:

16Mo3 Seamless Steel Pipe Yield strength ReH or RP0.2

Wall Thickness mm

Mpa

T ≤16

280

16<T≤40

270

40<T≤60

260

  • 16Mo3 Chrome Moly Steel Pipes Tensile strength, Rm, Mpa: 450 to 600

Minimum elongation A, %.

Longitudinal Transverse

22

20

  • 16Mo3 Alloy Steel Pipe Impact performance (optional).

Test temperature: 20°C, minimum average absorbed energy value KV J.

Longitudinal Transverse

40

27

  • 16Mo3 Seamless Alloy Steel Tube Minimum yield strength at elevated temperatures Rp0.2 (optional):

Wall thickness, mm: ≤60

Temperature℃

Mpa

100

243

150

237

200

224

250

205

300

173

350

159

400

156

450

150

500

146

16Mo3 high-temperature resistance pipes 

  • Outside diameter and wall thickness tolerances

OD: ±1% or 0.5mm whichever is greater

Wall thickness.

O.D.

Wall thickness tolerance, For T/D ratio

≤0.025

>0.025

≤0.050

>0.050

≤0.10

>0.1

D≤219.1

12.5% or 0.4mm take the biggest one

D>219.1

20%

15%

12.5%

10%

For OD D ≥ 355.6 mm the local wall thickness tolerance is allowed to exceed 5% of the specified base.

  • Tolerance of fixed-length

Length L

Length Tolerance

L ≤ 6000

0, +10

6000<L ≤12000

0, +15

L>12000

0, according agreement