What is the difference between trunnion and floating ball valves

Aug 12, 2025

Differences in Structure and Operating Principles

1. Trunnion Ball Valve:

- The ball is fixed to the valve body by two shafts, one above and one below. During rotation, only the ball moves; the shafts do not.

- Sealing relies on seat preload and media pressure. The seat is typically spring-loaded (e.g., made of PTFE) to ensure tightness under high pressure.

- Typical pressure rating: Class 150 to 2500 (referring to ASME B16.34), with diameters up to DN1200 and above.

2. Floating Ball Valve:

- The ball is connected only by the bottom stem. Media pressure pushes the ball against the outlet seat, creating a seal.

- While simple in structure, seal failure can occur due to ball displacement under high pressure. Suitable for Classes 150 to 300, with diameters generally smaller than DN300.

Carbon Steel Trunnion Ball Valve

Performance and Application Comparison

1. Sealing:

- Trunnion-mounted ball valves offer superior bidirectional sealing performance, achieving leakage levels up to Class VI (ISO 5208 standard); floating ball valves are mostly unidirectional, with leakage levels typically reaching Class IV.

2. Lifespan and Maintenance:

- Trunnion-mounted ball valve seats wear evenly, with a lifespan of over 100,000 cycles (according to API 6D testing); floating ball valve seats wear on one side, with a lifespan of approximately 30,000 to 50,000 cycles.

- Trunnion-mounted ball valve repairs require disassembly of the entire valve, while floating ball valve seats can be replaced online.

3. Cost:

- Floating ball valves are 30% to 50% cheaper and are suitable for medium and low-pressure applications with limited budgets. Trunnion-mounted ball valves are used for high-temperature and high-pressure applications (such as oil pipelines, pressures ≥10 MPa).

Carbon Steel Floating Ball Valves

Selection Recommendations

- Floating ball valves are preferred for small diameters (≤DN200), low pressures (≤PN40), and frequent opening and closing (such as tap water systems).

- Preferred fixed ball valves: Large diameter, high pressure, long-distance pipelines (such as natural gas pipelines), or corrosive media (requiring valve seats made of special materials).

Additional Notes:

- Fixed ball valves are recommended for high-temperature operating conditions (>200°C) as the floating structure is susceptible to thermal deformation.

- Floating ball valves have lower torque requirements (approximately 60% of fixed ball valves) and are suitable for manual operation.