Precautions For Globe Valve Operation And Maintenance
Aug 15, 2025
Globe valves are widely used due to minimal friction between sealing surfaces during operation, durability, compact design, ease of manufacturing/maintenance, and compatibility with various pressures.
Key operational precautions include:
Operate only in fully open or fully closed states. Never use for flow regulation, as partial opening erodes sealing surfaces and accelerates wear15.
Open/close using handwheel only. Avoid levers or tools to prevent valve damage.
Rotate clockwise to close; counterclockwise to open.
Maintenance Guidelines
Ensure valve components are complete and intact:
Flange and bracket bolts must be present with undamaged threads and zero looseness8.
Tighten handwheel nuts promptly if loose to prevent joint wear or loss of handwheel/nameplate. Replace lost handwheels immediately-never substitute with adjustable wrenches.
Keep stuffing box gland aligned with uniform pre-tightening gaps.
Install stem protective covers in environments exposed to rain, snow, dust, or sand. Maintain legible scales and intact lead seals, caps, and pneumatic accessories.
Inspect insulation jackets for dents or cracks