L290 Spiral Steel Pipe
Pipe ends: Plain, bevelled 30° with 1.6 mm root face, or as agreed
Coating: 3LPE, 3LPP, FBE, coal tar epoxy, concrete weight coating, black varnish
Documentation: EN 10204 3.1; 3.2 where third-party witnessing is specified
Gnee Steel (Tianjin) Co., Ltd. is one of the most reliable manufacturers and suppliers of l290 spiral steel pipe in China, also supports customized service with low price. Welcome to wholesale discount l290 spiral steel pipe for sale here from our factory. Contact us for free sample.
L290 is the ISO 3183 name for API 5L X42: a minimum yield of 290 MPa, a minimum tensile of 415 MPa. On its own that is an unremarkable grade, and it has been made seamless and ERW for sixty years. What makes it worth a page of its own is the route. Wound into a spiral seam, L290 reaches diameters of 3 m and above from coil that no other process can use at that size, and it does so at a wall of 10 to 20 mm and a pressure of about 5 MPa. That combination - large diameter, moderate wall, low pressure, low cost per tonne - is the spiral mill's home ground, and L290 is the grade most often standing on it.
The grade is also the reason the route works at all. Cold forming a pipe from coil adds yield strength, somewhere between 20 and 50 MPa depending on the wall and the amount of deformation. At L290 PSL2 the yield may sit anywhere between 290 and 495 MPa, a window of 205 MPa - 71% of the minimum. Forming strain fits inside that window with room to spare. At X70 the same window is 150 MPa on a 485 MPa base, 31% of the minimum, and a coil delivered at the top of its range can be pushed over the ceiling by the forming operation alone. This is why spiral pipe is bought in low grades far more often than in high ones, and why a coil order for L290M is a more forgiving document than the same order written for X70M.
L290 Spiral Steel Pipe Specifications
| Parameter | Specification |
|---|---|
| Product | L290 spiral welded steel pipe, SSAW / HSAW, single helical seam |
| Grade | L290 / X42; PSL1 or PSL2 |
| Standard | API 5L 45th or 46th edition; ISO 3183; GB/T 9711 equivalent |
| Delivery condition | R (as-rolled) or M (thermomechanically rolled) in practice; N on request where normalised coil is available; Q not offered on this route |
| Outside diameter | 219.1–3048 mm (8–120 in), mill and coil dependent |
| Wall thickness | 5.0–25.4 mm, limited by coil supply rather than by the grade |
| Length | 6 m, 11–13 m and 18 m standard; up to 24 m on some lines |
| Seam | Helical, one continuous seam, submerged arc welded inside and out |
| Helix angle | 55–75° to the pipe axis, set by coil width |
| Yield strength | 290 MPa min (42,100 psi); 495 MPa max at PSL2 |
| Tensile strength | 415 MPa min (60,200 psi); 655 MPa max at PSL2 |
| Weld seam tensile | 415 MPa min, both levels |
| Elongation | Per API 5L formula; 23% at Axc 130 mm², 20% at 65 mm², 29% at 485 mm² |
| Charpy, PSL2 | 27 J pipe body at 0 °C up to 762 mm OD; 40 J above; 27 J seam and HAZ |
| Hydrostatic test | Every joint, 60–90% of specified minimum yield, 10 s hold above 457 mm |
| Pipe ends | Plain, bevelled 30° with 1.6 mm root face, or as agreed |
| Coating | 3LPE, 3LPP, FBE, coal tar epoxy, concrete weight coating, black varnish |
| Documentation | EN 10204 3.1; 3.2 where third-party witnessing is specified |
Wall thickness is a coil question before it is a grade question. TMCP coil above 25.4 mm is scarce and expensive, so a 1420 mm pipe at 28 mm wall is not an L290 spiral enquiry at all - it is an LSAW enquiry, and the sooner that is established the less time is wasted on both sides.
Chemical Composition
L290 is a plain carbon-manganese steel with no deliberate microalloying at PSL1 and a tightly capped one at PSL2. The two levels differ less in the element limits than in what PSL2 adds around them: a carbon equivalent ceiling, and a requirement that it be calculated and reported.
| Element, % max | PSL1 welded | PSL2 L290R / L290N | PSL2 L290M | PSL2 L290Q |
|---|---|---|---|---|
| C | 0.26 | 0.24 | 0.22 | 0.18 |
| Si | - | 0.40 | 0.45 | 0.45 |
| Mn | 1.30 | 1.20 | 1.30 | 1.40 |
| P | 0.030 | 0.025 | 0.025 | 0.025 |
| S | 0.030 | 0.015 | 0.015 | 0.015 |
| V | - | 0.06 | 0.05 | 0.05 |
| Nb | - | 0.05 | 0.05 | 0.05 |
| Ti | - | 0.04 | 0.04 | 0.04 |
| Nb + V + Ti, combined | 0.15 | 0.15 | 0.15 | 0.15 |
| Cu / Ni / Cr / Mo | 0.50 / 0.50 / 0.50 / 0.15 | 0.50 / 0.30 / 0.30 / 0.15 | ||
| CEIIW / CEPcm | No limit | 0.43 / 0.25 | 0.43 / 0.25 | 0.43 / 0.25 |
| Seamless counterpart C limit | 0.28 for seamless PSL1; there is no seamless L290M | |||
For every 0.01% that carbon falls below its maximum, manganese may rise 0.05% above its own, to a cap of 1.65% at this grade. Carbon equivalent is calculated as CEIIW above 0.12% carbon and as CEPcm at or below it. At L290 the PSL2 grades all sit above 0.12% carbon at their limits, so CEIIW is the number that will appear on the certificate unless the mill deliberately goes low-carbon.
Two figures are worth carrying in your head. At their element maxima, L290R and L290N calculate to 0.440 and L290M to 0.437, both of which are above the 0.43 ceiling; L290Q calculates to 0.413 and clears it. In other words the carbon and manganese maxima in those two columns cannot be taken together, and a certificate showing 0.21% carbon with 1.15% manganese is not a mill cutting corners - it is a mill holding the limit that actually binds. And because the manganese credit trades 0.01 of carbon for 0.05 of manganese, worth 0.008 on carbon equivalent, walking the credit to its end barely moves the number at all. The grade that fits the ceiling exactly is Q, at 0.18% carbon and 1.40% manganese.
Mechanical Properties
PSL1
| Property | Requirement |
|---|---|
| Yield strength Rt0.5 | 290 MPa min (42,100 psi) |
| Tensile strength Rm | 415 MPa min (60,200 psi) |
| Weld seam tensile | 415 MPa min |
| Yield to tensile ratio | Not specified |
| Elongation, 2 in | Per formula, about 23% |
| Charpy impact | Not required |
PSL2, additional limits
| Property | Requirement |
|---|---|
| Yield strength | 290–495 MPa (42,100–71,800 psi) |
| Tensile strength | 415–655 MPa (60,200–95,000 psi) |
| Yield to tensile ratio, OD > 323.9 mm | ≤ 0.93 |
| Charpy, pipe body, 0 °C | 27 J up to 762 mm OD; 40 J above 762 mm |
| Charpy, seam and HAZ, 0 °C | 27 J average of three |
| Carbon equivalent | 0.43 CEIIW or 0.25 CEPcm, reported |
A 655 MPa tensile ceiling, not 760 - the higher figure belongs to grades above X46. The 0.93 ratio applies only above 323.9 mm outside diameter, which every spiral pipe clears.
What those numbers mean in pressure is more useful than the numbers themselves, and it surprises people who expect pressure capability to rise with diameter. It does not, because mills hold the diameter-to-wall ratio in a narrow band rather than scaling wall with size.
| Outside diameter | Typical wall | D/t | Pressure at F = 0.72 | Weight |
|---|---|---|---|---|
| 610 mm | 8.0 mm | 76 | 5.5 MPa | 118.8 kg/m |
| 813 mm | 10.0 mm | 81 | 5.1 MPa | 198.0 kg/m |
| 1016 mm | 12.0 mm | 85 | 4.9 MPa | 297.1 kg/m |
| 1220 mm | 14.0 mm | 87 | 4.8 MPa | 416.4 kg/m |
| 1420 mm | 16.0 mm | 89 | 4.7 MPa | 554.0 kg/m |
| 2032 mm | 20.0 mm | 102 | 4.1 MPa | 992.3 kg/m |
| 2540 mm | 22.0 mm | 116 | 3.6 MPa | 1366.1 kg/m |
Barlow, P = 2St/D, with S at 290 MPa and a design factor of 0.72. Weight from (D − t) × t × 0.02466.
An L290 spiral is therefore a four to five megapascal product at almost any diameter. Doubling the diameter from 1220 to 2540 mm adds 950 kg per metre and takes 1.2 MPa off the rating. If the design calls for 8 MPa at 1420 mm, the wall required is 27.2 mm - above the coil ceiling, and above what this route does well. That is not a failure of the grade; it is the boundary of the product, and it is better established in the first email than in the third revision of a quotation.
Spiral Pipe Manufacturing Process
L290 spiral pipe is produced by continuously bending steel coil into a helical tube and welding the spiral seam inside and outside with submerged arc. The grade is decided before the pipe exists, because the delivery condition travels with the coil rather than being created at the pipe mill - a point that matters more on this route than on any other.
Key production process includes:
Raw material inspection. Coil is checked against the mill certificate for heat number, chemistry, carbon equivalent and mechanical properties, and the coil width is confirmed against the diameter to be run.
Strip edge milling. Both edges are milled to a controlled width and square face. This is not cosmetic: the weld is made between two prepared edges, and an unprepared edge is where lack of fusion starts.
Coil handling and end welding. Coils are joined end to end to keep the line running. In finished helical pipe those joints are permitted, but the junction with the spiral must sit at least 300 mm from the pipe ends.
Internal welding. A multi-wire submerged arc pass is made on the inside of the spiral as the pipe advances.
External welding. The outside pass follows, typically with more wires and higher current, and completes the double-sided seam.
Weld inspection. The seam is examined by ultrasonic or radiographic testing over its full length, with the beam angled to catch planar defects lying along the fusion line.
Hydrostatic testing. Every joint is tested, held for at least ten seconds above 457 mm diameter, at a pressure set by the mill between 60% and 90% of the specified minimum yield.
End finishing. Ends are squared, sized and bevelled. Spiral pipe is not cold expanded along the barrel the way LSAW is, so diameter and roundness are held at the ends by sizing rather than by expanding the whole length.
Final inspection and marking. Dimensions, bevel, visual condition, coating if applied, and the stencil carrying standard, grade, size, heat number and mill mark.
Three consequences follow from this sequence, and all three are worth knowing before a specification is written. First, the metallurgy is fixed upstream: a spiral mill cannot normalise or quench a finished 18 m joint, so a call for L290N means buying normalised coil, and normalised coil above about 12 mm is thin on the ground. In practice L290 spiral ships as M, from TMCP coil, with the properties specified as pipe properties and demonstrated on the finished pipe. Second, the forming operation itself adds yield: outer fibre strain is roughly t/D, which is 1.1 to 1.2% at these sizes, and that cold work lifts yield by tens of megapascals. A coil bought at the top of its strength range can therefore produce pipe outside the PSL2 ceiling without anything going wrong on the line. Third, the seam is long: at 1420 mm from 1500 mm coil the strip sits at about 70° and every metre of pipe carries 2.97 m of seam, so a 12 m joint carries 35.7 m. Welding consumables, inspection time and the probability of finding an indication all scale with that number rather than with the tonnage.
Applications of L290 Spiral Steel Pipe
| Application | Typical use |
|---|---|
| Water transmission mains | Raw water, treated water and irrigation lines from 800 to 3000 mm, usually cement-mortar or epoxy lined |
| Low-pressure gas pipelines | Distribution mains and secondary transmission at 2–5 MPa, 3LPE coated with impressed current protection |
| Pumped storage and penstocks | Hydro penstock and surge shaft liners, where large diameter and stiff walls matter more than grade |
| Slurry and tailings lines | Mining duty with a wear allowance added to the wall and an internal lining |
| Piling and foundation | Bearing piles and sheet piles; specify ASTM A252 for anything carrying structural load |
| Structural tube | Large-diameter columns, trusses and crane booms in non-pressure duty |
| Outfalls and drainage | Sea outfalls, stormwater and culvert liners in corrosion-resistant coating systems |
The line between the first two rows and the fifth is a standard, not a grade. A252 pipe is ordered around driving and splice strength and does not require a hydrostatic test; API 5L pipe is ordered around pressure containment and always does. Using one where the other belongs is the most common specification error at this diameter.
L290 vs X42 vs L245 (Grade B)
The first two columns of this table are the same steel. L290 is the ISO 3183 designation, X42 the API 5L designation, and both mean a minimum yield of 290 MPa. The real step is the third column: L245, which is Grade B, 45 MPa lower in yield and identical in tensile.
| Property | L290 spiral | X42 (L290) | L245 (Grade B) |
|---|---|---|---|
| Minimum yield | 290 MPa | 290 MPa | 245 MPa |
| Minimum tensile | 415 MPa | 415 MPa | 415 MPa |
| PSL2 yield range | 290–495 MPa | 290–495 MPa | 245–450 MPa |
| Forming route | Helical seam from coil | Seamless, ERW or SAW | Seamless, ERW or SAW |
| Usual diameter band | 600–3000 mm | Up to 1500 mm | Up to 1200 mm |
| Wall needed at 4 MPa, 1016 mm | 9.73 mm | 9.73 mm | 11.52 mm |
| Weight at that wall | 241.5 kg/m | 241.5 kg/m | 285.3 kg/m |
| Relative position | Same grade, different route | 15.4% heavier at equal pressure | |
Barlow with F = 0.72, no corrosion allowance. The 15.4% is not a coincidence: 245/290 is fixed, so the ratio holds at any diameter and pressure where the wall is pressure-controlled.
Against L245, L290 buys 15% of the steel back. Against X42 there is nothing to buy - the useful comparison there is route, not grade, and route is decided by diameter and wall. Below 600 mm, ERW makes the pipe more cheaply and with a shorter seam. Between 600 and 1500 mm, ERW, LSAW and spiral all compete and the winner depends on wall: LSAW takes the heavy end, spiral the light end. Above 1500 mm there is only spiral, because no other process can form a plate that wide at a price anyone will pay.
Quality Inspection and Documentation
For L290 spiral pipe, a purchase should include the following inspection and documentation requirements, whether or not the standard demands every one of them.
| Inspection item | Requirement |
|---|---|
| Visual and dimensional | Every joint: outside diameter, wall at the seam and 90° away, length, end squareness, bevel angle and root face, straightness |
| Chemical analysis | Ladle and product analysis per heat; carbon equivalent calculated and reported at PSL2 |
| Tensile testing | One test per test unit; pipe body and weld seam, with the weld not permitted to fall below the body minimum |
| Charpy impact | PSL2 only: body, seam and heat-affected zone at 0 °C, 27 J average, 20 J individual |
| Hydrostatic test | Every joint, pressure and hold time recorded against the joint number |
| Non-destructive testing | 100% seam inspection by ultrasonic or radiographic method at PSL2; on request at PSL1 |
| Coating inspection | Holiday test over the full length, dry film thickness, adhesion and visual; concrete weight coating by density and thickness |
| Documentation | EN 10204 3.1 inspection certificate as standard; 3.2 where a third party witnesses testing; NACE MR0175 only when the pipe is ordered for sour service |
A PSL1 order without a written inspection clause receives a hydrostatic test and a certificate if one was asked for. Traceability at PSL1 is required only until the tests are passed, which is why PSL1 pipe often arrives with paperwork that cannot be tied back to the joint on the ground.
Surface Coating Options
3LPE coating
Three-layer polyethylene: epoxy primer, copolymer adhesive, polyethylene topcoat. The default for buried water and gas lines. Good mechanical damage resistance, service to about 70 °C.
FBE coating
Fusion bonded epoxy, single layer, 300–500 µm. Best where the pipe will be handled hard or the operating temperature is high; less tolerant of ultraviolet before burial.
Concrete weight coating
Reinforced cement mortar for buoyancy control on submerged lines, applied over the corrosion coating, with a density of 2.2–3.0 t/m³ depending on the specification.
Test and inspection



Packaging and shipping

Send The Schedule And We Will Come Back With A Route
Diameter, wall or pressure, total length, service, coating and destination port. We will confirm whether the wall you need is available in coil, whether L290 spiral is the right route at that size, and what the seam treatment and inspection coverage should be. If the answer is LSAW or a higher grade, we will say so.
FAQ
Is L290 the same as X42?
Yes. L290 is the designation used by ISO 3183 and GB/T 9711, X42 is the designation used by API 5L, and both specify a minimum yield of 290 MPa (42,100 psi) and a minimum tensile of 415 MPa (60,200 psi). The chemistry tables, strength ranges and test requirements are identical. Either name can be written on a purchase order, and a mill will normally print both on the certificate.
Is L290 spiral pipe suitable for water?
It is one of the most common choices for it. Large-diameter water mains run at 1 to 4 MPa, which sits comfortably inside the 4–5.5 MPa an L290 spiral holds at normal wall, and the pipe is available in diameters that ERW cannot reach. Cement mortar lining to AWWA C205 or epoxy lining to AWWA C210 is normally added, and the external coating is chosen for the ground conditions. The one requirement worth stating explicitly is that the lining be applied after hydrostatic testing, so the test water does not get trapped behind it.
What is the difference between L290, L290N, L290M and L290Q?
The letters are delivery conditions and they belong to PSL2. L290R is as-rolled, L290N is normalised, L290M is thermomechanically rolled and L290Q is quenched and tempered. All four carry the same strength window and the same carbon equivalent ceiling; they differ in how the microstructure was obtained. On a spiral line the practical answer is that the condition comes with the coil, so M is standard, N requires normalised coil, and Q is not offered at all - a spiral mill has no quench and temper capability for an 18 m finished joint.
Can L290 spiral steel pipe be supplied with 3LPE coating?
Yes, and it is the most common coating for buried service at this size. Three-layer polyethylene is applied in a side-extrusion or cross-head process after the pipe has passed the hydrostatic test, with the cut-back length set by the girth welding procedure. For lines that will carry a concrete weight coating for buoyancy, that coating goes over the 3LPE, and the two systems have to be specified together because the weight coating application temperature can damage a thin corrosion coating.
What certificates come with L290 spiral steel pipe?
An EN 10204 3.1 inspection certificate is the normal document, issued against the specific heat and test unit, carrying chemistry, tensile results, Charpy results at PSL2, hydrostatic test pressure and the standard edition. A 3.2 certificate is available when a third-party inspector witnesses the testing, and it is worth specifying on any line where the buyer will not have its own inspector at the mill. NACE MR0175 is a separate qualification and should not be assumed from an API 5L certificate.
Hot Tags: l290 spiral steel pipe, China l290 spiral steel pipe manufacturers, suppliers, factory, SY T 5040 SSAW Pipe For Piling, A335 P1 Welded Carbon Steel Tube, SY T5037 Steel Pipe, spiral steel pipe, China Q345 Welded Steel Tube, welded seam steel pipe
Send Inquiry